TRUNNION DESIGN BALL VALVE
 
Features:
  • General design standard:  API6D
  • Pressure-temperature rating: ASME B16.34 
  • Face to face dimensions: ASME B16.10 
  • Flange type and dimensions:  ASME B16.5 
  • Butt-welded ends: ASME B16.25 
  • Inspection and test:  API598
1.Up stream Sealing Two-way Valve
The up stream seal of the Valve is fulfilled by the advanced spring pre-tightened seat package which has a feature of self-tightness. The two-way valve has two seats that can be sealed on two directions, with no limitation of flow direction during installation.

 

 

 

 

2.Double Block &Bleed Valve
Spring loaded up and downstream sealing, the valve can bleed out the trapped fluid in the body cavity when the valves is in fully open or fully close position. the fluid is intercepted by seats of up stream and down stream side. So, the stem packing or O-ring may be replaced under working pressure. And to bleed the dirty fluid periodically can reduce damage of the sealing surface and prolong the service life of the valve.

 

 

3.Automatic Relief of the Cavity:
If the pressure of the body cavity unusually goes up, Flo-Tite valve can automatically relieve the pressure by compressing the spring in the spring pre-tightened seat package.

 

 

 

 

4.Full Bore or Reduce Bore:
Either full bore or reduce bore can be available according to customers' requirements. For full bore type, the diameter of the valve ball bore is the same as the pipe size, which facilitates pigging operation.

 

 

5.Fireproof Design:
When the non-metal seats are softened and burnt in case of the fire or unusual temperature increase, the seat retainer, under the duty of the spring, will make contact with the ball and form a metal-to-metal seal, which can prevent internal leak: meanwhile, the middle flange and the upper part and lower part of the stem will form a metal-to-metal contact which can prevent external leak and conform to API6FA or API607.

 

 

 

 

 

 

 

 

6.Secondary Emergency Sealing
When seat and stem sealing system is damaged, the grease injection valve can inject sealing grease into the valve for temporary sealing.
 

 

 

 

 

 

 

 

 

 

 

7.Stem Sealing System
Two O-rings are adopted in/out the stem position with reliable performance.

 

 

 

8.Stem Extension
According to installation or operation need, the valve stem may be extended. This design is suitable for under ground application. The stem extension length can be manufactured to meet customer requirements.

 

9.Flexible Operation.
The seat and stem bearing adopt Teflon with small friction and self-lubrication to reduce the valve operation torque. The valve can be easily operated for long period even with no sealing lubrication grease.

 

10.Multi-Operation Type.
The valve may be operated by hand, pneumatic operator, motor, hydro-pneumatic operator and hydraulic operator, etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 